ASHRAE releases best practice guide for liquid cooling systems in data centers

ASHRAE releases best practice guide for liquid cooling systems in data centers

The publication provides guidelines on interface requirements between chilled-water systems and technology cooling systems and on the requirements of liquid-cooled systems that attach to a datacom electronics rack.


By BD+C Staff | May 22, 2014
Photo: Fleshas via Wikimedia Commons
Photo: Fleshas via Wikimedia Commons

ASHRAE recently released “Liquid Cooling Guidelines for Datacom Equipment Centers,” second edition, a guide for implementing liquid cooling systems in data centers. The guide provides guidelines on interface requirements between chilled-water systems and technology cooling systems and on the requirements of liquid-cooled systems that attach to a datacom electronics rack.

Data center rack heat loads are steadily climbing, creating a need for liquid cooling solutions to reduce the volume of airflow needed, ASHRAE says. “There is an increasing interest in liquid-cooled IT equipment at the rack, equipment and component levels,” says Don Beaty, publication chair of Technical Committee 9.9., Mission Critical Facilities, Data Centers, Technology Spaces and Electronic Equipment. “There is also increased interest in reuse of the heat rejected from IT equipment. One of the more important changes to the second edition is the addition of supply water temperature classification.”

The addition of liquid classes can have a similar effect on the industry as the creation of supply air temperature classes did—which was the critical enabler to the use of economizers in data centers, Beaty says. “There are five water temperature classes with the highest temperature class being >45 C (113 F), which opens up possibilities for using the rejected heat for building heating systems,” he said.

(https://www.ashrae.org/news/2014/supply-water-temperature-classification-new-addition-to-updated-guidance-on-cooling-data-centers)

Related Stories

Codes and Standards | Jul 27, 2021

Add a wobbly moon to flooding risk factors

Earth satellite’s orbit variations will lead to sunny-day flooding in the mid-2030s.

Codes and Standards | Jul 26, 2021

Revamping of Florida building codes on the table after condo collapse

Tragedy could prompt upgrades like post-Hurricane Andrew effort.

Codes and Standards | Jul 21, 2021

Proposal to give Calif. hospitals more time for earthquake retrofits stirs controversy

State hospital association says 2030 deadline should be extended.

Codes and Standards | Jul 20, 2021

New York, New Jersey legislatures may revamp bidding rules to promote low-carbon concrete

Contractors would have to certify that their concrete is in compliance.

Codes and Standards | Jul 19, 2021

Lack of information on carbon emissions challenges construction industry

Reports recommends whole-life carbon assessments on building projects.

Codes and Standards | Jul 15, 2021

Three drywall code-referenced publications have been updated

Include guidance on fire resistance, sound control, application, and finishing.

Codes and Standards | Jul 14, 2021

Biden’s infrastructure proposal includes massive investment in school buildings

‘Once in a lifetime opportunity’ to upgrade HVAC and other key systems.

Codes and Standards | Jul 13, 2021

Reluctance to fund maintenance on older condos is a serious problem

Owner associations defer needed work, putting properties at risk.

Codes and Standards | Jul 12, 2021

Regulations on hydrofluorocarbons reduce roof insulation options

Canada, some U.S. states ban HFC blowing agents used in closed-cell foam.

boombox1
boombox2
native1

More In Category




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021