There are several ways to prevent moisture from building up in your attic available in today’s marketplace, what is the best way?  Keep in mind that different climatic areas can alter the recommendations. Proper static airflow that equalizes pressure in the attic without depending on a completely sealed system or a power vent is a great way to go! Let’s look at why.
My home, built in 1984 with a hip roof using some good old-fashioned soffit vents and nothing else. The first thing I did when buying it in 1996 since I only knew enough at that time to realize that it was necessary to move the air, was cut a hole in the roof for a temperature-controlled power exhaust fan within 3’ of the ridge.  When I cut that opening, the wind generated by the heat escaping the attic felt like a giant hairdryer just turned on! Pleased with the obvious result I installed the powered exhaust fan and would then purchasetwo more of them over the next 3 years as they continually burned out. The roof area was far too large for the fan sucking 150* air out of a hip roof attic. My answer came by way of a hailstorm destroying my roof in year 3 and learning the advantages of continuous soffit vents, vented ridge, and staticair movement over powered systems. So far, 24 years passed without issues!
Sealed attics with high R factor insulation are another method to achieve dryness in that cave above your home. However, it is dependent on the powered HVAC system to work year after year and of the sensors malfunction, the moisture can build up beyond a bit of mold when you unknowingly have a system out of order for months. Even if it works properly, sometimes after-market changes or structure settling can cause gaps in the sealed insulation. With the new materials and tighter construction methods, moisture issues can fester for months causing health issues and structural damage before being noticed.Â
The bottom line is you start at the soffit with a system like the Tamlyn continuous vents that provide ample static air movement for the attic space without depending on mechanically forced air that will last the life of the property. They begin with a minimum NFA (Net Free Area) of 9” per lineal foot for the beginnings of a great ventilation system. ICC code R806.2 of 2015, commonly used today and states that ventilation must be 1/150 NFA of the area in the ventilated attic space, barring exceptions.
Beware of using boards or other soffit material that has holes punched into them and called a built-in soffit vent. You can only place so many holes in those products before they lose strength to hold up, and due to their thickness versus real vents, wind shear tremendously reduces the manufactures NFA ratings.
Naturally, for best practice, use a continuous soffit vent that delivers at least an NFA rating of 9” per lineal foot for all soffit applications.Additional benefits of Tamlyn’s continuous vents are the aesthetic styles, materials, and more robust NFA options available. Start your journey to attic and structure health at https://tamlyn.com.
“When Doing it Right Matters”
More from Author
TAMLYN | Apr 8, 2020
Moisture-managing mounting blocks offer great margins – and meet growing needs of builders
Currently, when it comes to water management systems for openings such as vents and electrical, many builders simply tape around the opening and cover it with a makeshift treated piece of trim board.
TAMLYN | Jan 29, 2020
Choosing the Right Product to Avoid Water Damaged Walls
Walls using rainscreens go a long way towards a water-tight envelope
TAMLYN | Nov 7, 2019
Rainscreens for longer-lasting homes
Rainscreen walls go a long way towards a tighter envelope.
TAMLYN | Aug 21, 2019
Easy steps to avoid water damaged walls
Rainscreen walls go a long way towards a water-tight envelope.
TAMLYN | Jun 19, 2019
Will your vendor let you down? 4 vital questions to ask
To determine if your vendor has the right stuff to deliver what the crew needs at the right time and in good condition, here are four vital questions to ask.
TAMLYN | Mar 29, 2019
Moisture-managing mounting blocks offer great margins — and meet growing needs of builders
It’s important to educate — and upsell — builders on smaller detail pieces that have higher margins.
TAMLYN | Jan 18, 2019
Tamlyn and the University of Houston partner to educate the architects of tomorrow
Visits with working architects, builders and product manufacturers bring concepts to life and prepare architectural students for the first steps in their careers.
TAMLYN | Dec 17, 2018
Versatile trim creates modern look without blowing the budget
An off-the-shelf trim gives a mixed-used development a sleek, custom aesthetic.
TAMLYN | Dec 5, 2018
Ask these 5 crucial questions before choosing and installing drainable wraps
One third to one half of all structures have damp conditions that may encourage development of pollutants such as molds.
TAMLYN | Nov 26, 2018
Quality customer service delivered every day at TAMLYN
When everything is going as expected, every company is there for you. If it goes bad, they’ll show their true colors, leaving you in a bind.