A massive, colorful, moving mural creatively conceals a newly opened, four-level, 520,000-sf parking garage for a global technology company in Mountain View, Calif. Linetec finished 111,692 individual metal flappers in 35 different colors to compose the wind-activated KINETICWALL system manufactured by EXTECH/Exterior Technologies, Inc.
The parking structure itself was designed by Gensler and International Parking Design. The building owner commissioned paintings by Los Angeles-based artist Kim West to depict different seasons of Mountain View’s natural landscape. The original artwork was then digitized by art consultant Selbert Perkins Design. For each pixel, Linetec finished an 8-by-8-inch extruded aluminum flapper panel in the corresponding color. To achieve the pixelated mural effect, 35 unique colors were chosen to match West’s original artwork.
When wind passes through the building façade’s KINETICWALL system, the thousands of painted “pixels” within the illustrated landscape move in response. “Kinetics express wind wave patterns as the elements move in sequence from light to dark as they catch light,” explained Kevin Smith, director of product application and development at EXTECH.
For more than a decade, EXTECH and Linetec have collaborated on successful projects. In 2016, they worked together on the KINETICWALL installation at Boston’s Logan International Airport’s parking garage extension consisting of more than 48,000 anodized aluminum flapper panels.
“EXTECH’s projects with dynamic façade systems are always interesting and exciting,” said Linetec’s director of marketing, Tammy Schroeder. “This California tech company project is definitely one of the most colorful and impressive projects that I can recall Linetec ever doing.” According to EXTECH, it also is the largest KINETICWALL project to be completed in the U.S.
Parking garage mural blends artistry and functionality
As an artist, West selected Pantone colors used in graphic design and printing. To ensure durable, high performance that maintains the intended visual impression and longevity, the color selections were matched in 70% PVDF resin-based architectural coating systems. Linetec meticulously adjusted each paint formulation for approval by EXTECH and West.
Once all 35 colors were approved, Linetec applied the finish to the designated quantity of metal flapper panels at its Wisconsin-based facility. Specified to meet stringent AAMA 2605 industry standards, 70% PVDF resin-based coatings exhibit outstanding resistance to humidity, color change, chalk, gloss loss and chemicals. These colorful finishes also resist fading under California’s sunny skies and have passed at least 4,000 hours of salt spray testing to demonstrate performance under coastal conditions.
During the design process, EXTECH fabricated four different study mock-ups plus a one-story on-site mock-up to confirm its KINETICWALL system achieved the project’s artistic and performance requirements. Once the order was approved and processed, Linetec finished and shipped the painted aluminum components to EXTECH’S manufacturing headquarters in Pittsburgh for assembly. Each kinetic element was oriented and positioned in place to align with the artist’s vision. The flapper panels are set within extruded aluminum framing support assemblies that span each of the building’s elevations.
EXTECH’s engineering team mapped out where each flapper element would go, color-coordinating and labeling sections to determine where an element would be assembled and ultimately installed by Arrow Sign Company. The project’s entire KINTECWALL system was sequenced and shipped to the jobsite in approximately 90 truckloads to coordinate with the phased installation. Throughout the installation, EXTECH provided detailed as-built drawings for each elevation, on-site inspections and assistance.
For the Mountain View parking facility project, EXTECH’s KINETICWALL uses a pin-mount suspension system, which allows the flapper elements to seemingly float in front of the support rungs and side rails as a veil. This configuration minimizes the appearance of the supporting structure and is more convenient when creating innovative aesthetic designs.
Along with its distinctive exterior appearance, the KINETICWALL provides a functional façade for shading and ventilating the parking structure, and offers visibility from the interior. The flapperwall’s pin-mount suspension, lightweight aluminum and unitized construction also facilitates installation, saving time and labor in the field. Each flapper element was mounted in pre-assembled “ladder and rung” panels. The dimensions of these unitized panels spanned more than 22 feet tall by 6 feet 8 inches wide.
Toward the bottom of the wall, up to 9 feet above grade, static flappers are manufactured with thicker gauge metal and mounted in a custom rung system. Together with stainless steel mesh, this project-specific design helps deter climbing on the exterior and vandalism from the interior. Pin-mount suspension systems allow the flappers to be removed and replaced without any specialized tools if repair or maintenance is needed. Linetec’s high-performance finishes further minimize the need for maintenance and maximize longevity.
Future-proofing for current and adaptive reuse
According to Clark-Pacific, the building owner sought to “future-proof” its capital investment by considering a 50-year operational outlook. “As a result, the project team was able to design and construct a parking structure that fulfills present requirements, while allowing for the flexibility to repurpose the building in the future. The structure was intentionally designed to facilitate adaptive reuse, enabling it to transform from a garage into an office building with minimal selective demolition, while preserving the overall structure and some of the existing systems.”
Currently, the building comprises 1,209 static parking stalls and 460 mechanical stackers. Clark-Pacific described the facility, noting, “Its tall ceiling heights and painted interior create a spacious and bright environment for users, and its dynamic exterior boasts a kinetic façade that replicates murals of the surrounding environment. Additionally, a pedestrian greenway connects the site to other areas on the campus, and the building includes extensive landscaping and user amenities, such as a 1-megawatt solar structure and 10,000 sf of retail space on the first level.”
“The unique, colorful, dynamic façade demonstrates how visual beauty and innovative technology can be combined to form a result where the whole is more impressive than the sum of its parts,” concluded Schroeder.
On the Building Team
Architects: Gensler, International Parking Design, Inc.
Mural Artist: Kim West
Engineer/Manufacturer – Façade System: EXTECH/Exterior Technologies, Inc.
Finishing Services – Façade System: Linetec
GC: Clark-Pacific
Related Stories
| Jan 2, 2014
Sacramento utility maintenance facility earns LEED Platinum, targets net zero
The Sacramento Municipal Utility District’s new maintenance facility, which is targeting net zero, has received LEED Platinum certification.
| Dec 17, 2013
Kahn appoints Alan Cobb President and CEO
Cobb is the tenth president in the firm’s 118-year history. As President, Cobb is responsible for ensuring that all of the firm’s client issues are effectively address and that overall project team performance meets or exceeds client expectations for each and job the firm undertakes.
| Dec 13, 2013
Safe and sound: 10 solutions for fire and life safety
From a dual fire-CO detector to an aspiration-sensing fire alarm, BD+C editors present a roundup of new fire and life safety products and technologies.
| Dec 10, 2013
16 great solutions for architects, engineers, and contractors
From a crowd-funded smart shovel to a why-didn’t-someone-do-this-sooner scheme for managing traffic in public restrooms, these ideas are noteworthy for creative problem-solving. Here are some of the most intriguing innovations the BD+C community has brought to our attention this year.
| Nov 27, 2013
Exclusive survey: Revenues increased at nearly half of AEC firms in 2013
Forty-six percent of the respondents to an exclusive BD+C survey of AEC professionals reported that revenues had increased this year compared to 2012, with another 24.2% saying cash flow had stayed the same.
| Nov 27, 2013
Wonder walls: 13 choices for the building envelope
BD+C editors present a roundup of the latest technologies and applications in exterior wall systems, from a tapered metal wall installation in Oklahoma to a textured precast concrete solution in North Carolina.
| Nov 26, 2013
Construction costs rise for 22nd straight month in November
Construction costs in North America rose for the 22nd consecutive month in November as labor costs continued to increase, amid growing industry concern over the tight availability of skilled workers.
| Nov 25, 2013
Building Teams need to help owners avoid 'operational stray'
"Operational stray" occurs when a building’s MEP systems don’t work the way they should. Even the most well-designed and constructed building can stray from perfection—and that can cost the owner a ton in unnecessary utility costs. But help is on the way.
| Nov 13, 2013
Installed capacity of geothermal heat pumps to grow by 150% by 2020, says study
The worldwide installed capacity of GHP systems will reach 127.4 gigawatts-thermal over the next seven years, growth of nearly 150%, according to a recent report from Navigant Research.
| Nov 6, 2013
Energy-efficiency measures paying off for commercial building owners, says BOMA study
The commercial real estate industry’s ongoing focus on energy efficiency has resulted in a downward trend in total operating expenses (3.9 percent drop, on average), according to BOMA's Experience Exchange Report.