flexiblefullpage
billboard
interstitial1
catfish1
Currently Reading

Considerations When Specifying in Extreme Weather Zones

Sponsored Content Voice of the Brand

Considerations When Specifying in Extreme Weather Zones

Why Choose an IMP in an Extreme Weather Zone? 


By Steven Huck, District Sales Manager at CENTRIA | March 31, 2023
Considerations When Specifying in Extreme Weather Zones

When hurricanes, tornados, extreme temperatures, snow and ice, or salty ocean air have the potential to impact a structure, it is critical to design a building envelope system that will protect the occupants from the elements and deliver a comfortable environment. In selecting a building envelope system, designers and architects need to weigh a variety of considerations. 

Tornado

For extreme weather zones, IMPs are the leader in each category and deliver the optimal solution.

1. Swings in temperatures 
A single component system like an insulated metal panel works in all seasons and is not impacted by temperature shifts. While the rule of thumb remains to install the air and water barrier toward the warm side, that approach leaves the system wrong half of the year in areas with four seasons and with large temperature swings and extreme temperatures. A universal wall system utilizing IMPs allows for appropriate thermal protection all the time and places the weather-resistant barrier on the control side of the wall managing condensation.

2. Thermal performance
The industry standard for thermal performance remains the R value. The insulative properties of IMPs can be measured two ways: through the R value of the foam interior of the panel or through the U factor of the complete panel system. Building based on a system measurement is critical to ensure thermal performance that is design specific. The key data point to review is the U factor that accounts for the system as a whole, which provides a more valuable and accurate look at the performance. IMPs improve thermal performance by forming air, water, and vapor barriers in one single component to protect the building from the elements. Since the exterior and interior skins of the panels are adhered to the foam core and there is no metal conductance between layers, thermal performance is greatly improved.

3. Integration
Building envelope solutions have evolved to be more energy efficient, but continuous insulation's ambiguity in the code and transitions from opaque wall areas to fenestrations and other penetrations through the envelope present opportunities for improved performance. Thermal imaging shows cold bands at those transitions when IMPs are not used. Integrated components like windows, louvers and sunshades improve the system transitions for thermal, air, and moisture protection. In extreme weather zones, that added protection is critical to ensuring high-performing structures and comfort for occupants. By installing insulated products designed to integrate with other exterior cladding like glass curtain walls and windows, designers can be confident that performance and protection will endure as a system and not leak at the transition seams.

4. Dew points 
When dew points are constantly changing, condensation can accumulate and soak traditional building envelope materials and can cause structural components to get wet. When temperatures are constantly changing or outside temperatures are drastically different than the dew point, the building’s walls will deposit bulk water and cause damage to the materials. IMPs place the dew point at an internal point of the panel, so the moisture-phobic foam and galvanized steel skins do not allow moister to enter. That prevents vapor from entering and condensation on any of the wall or structural components.

5. Wind loads 
When facing high wind loads, the IMP sandwich panel's torsion box effect ensures resistance to impact, and the skins do not separate from the foam. The ability to select from a wide range of steel gauges allows for additional load and impact capabilities. The thicker, factory-sealed, inspected panels are reliable and deliver a safer panel.

6. Testing requirements 
When specifying, it is critical to include the most up-to-date testing and performance requirements. With the ever-changing energy, fire, and performance code requirements, it can be a challenge to select a reputable manufacturer that can keep up with the scope of cladding systems. Great manufactures can provide industry-leading design and functional performance beyond the code-compliance minimums. IMPs allow designs to come to life while providing environmentally effective and occupant-centered spaces.

7. Carbon footprint
Specifying products that have Environmental Product Declarations (EPDs) and Underwriters’ Laboratories (UL) product declarations is a must. This ensures your building envelope is made without red-listed chemicals and through a process that has a low carbon footprint. It  is also an important consideration to a building’s journey to completion. Halogen-free foams and climate-conscious methods that are prevalent in the manufacturing of IMPs create better products for longer lifespans and better environmental performance.

8. Gauge 
When specifying an exterior cladding product, it is important to understand what the exterior has to contend with and pick the appropriate gauge, or thickness of the panel. IMPs can do gauges that range from 26-18 gauge on interiors and exteriors. In regions where extreme weather is a consideration, a good starting point is a 22-gauge panel to deliver a thicker and therefore stronger, more protective building envelope system to withstand the elements.

9. Installation 
IMPs can be installed in a single pass around a building or one trip up a tower, saving coordination of trades, equipment costs and reduced time on site for crews. Installation of IMPs is also not subject to weather conditions. They can be installed in cold or hot weather and even during rain, because the moisture cannot be trapped in the system or absorbed by the foam.

10. Finish 
In any weather zone, nearly any type of finish can be used on IMPs. In areas that are exposed to brackish water or salt air, it is best to select finishes that are more capable of resisting corrosive air. This may include stronger primers and clear coats. The facility and its function may also require material consideration. For example, at and around power plants, it is important to consider the PH levels of the processes occurring and upgrade interior finishes on panels to reduce potential corrosion. In extreme weather zones, considering the reflectivity of the panels is critical for safety as well as to ensure that sun reflections and glimmers will not disturb the surrounding environment or cause disruptions on roadways.

Insulated metal panels provide advanced air, thermal, and moisture protection performance, all in one single-component system. In extreme weather zones, the benefits of specifying an all-in-one building envelope system mean cost savings for installation, energy savings on building performance, and a building that endures the elements for the life of the building.

Centria

Related Stories

Sponsored | Voice of the Brand | Jul 2, 2020

Solving the Building Envelope Challenge

Today, solutions for the building envelope need to meet exacting standards on two equally important fronts – long-term performance and enduring aesthetic appeal. In this article, CENTRIA demonstrates how its products meet the standard in two different scenarios – construction of a new hospital in Asheville, North Carolina, and the addition to a popular museum in Pittsburgh. 

Sponsored | Voice of the Brand | Jun 5, 2020

Practice Style Transcendence with Brick

Get inspired! Brick’s adaptability has made it the premier building material for centuries even as styles come and go. Nothing says “classic” like brick, but nothing says “innovative” like brick either. Check out some examples of how fired clay brick remains a major presence in the 21st Century designer’s palette.

Sponsored | Voice of the Brand | May 7, 2020

How One Fabricator Uses ALPOLIC MCM as His Calling Card in the Residential Market

ALPOLIC metal composite materials have been used in the architectural and commercial building worlds for years. But recently, architects are starting to specify it for residential and other non-traditional applications.  With exceptional warranties and a variety of finishes, it is a perfect fit for homeowners wanting something different.

Sponsored | Voice of the Brand | May 5, 2020

Two Schools Go for Bold Color and Eye-Catching Design

Metal wall panel systems with varying rib patterns and pops of color provide dynamic visual interest in two different new-construction school buildings. PAC-CLAD Precision Series Panels offer an affordable array of 45 standard colors and 12 panel options for endless cladding possibilities.

Sponsored | Voice of the Brand | Mar 10, 2020

How Trim-Tex’s Fast Edge® corner bead saves time & material

Trim-Tex recently rolled out its latest vinyl corner bead innovation, Fast Edge®, promising to drastically cut down on the time and material it takes to finish drywall corners. How much can these corner beads actually save contractors? They put it to the test!

boombox1
boombox2
native1

More In Category

Voice of the Brand

Designs Inspired by Timber with Less Limitations

Explore new possibilities in your design with the natural look of wood, without the weight, maintenance difficulties, or expense. Three projects, featuring ALPOLIC’s Timber Series, highlight how metal composite materials provide beautiful, durable and safe solutions with a look so real, you’ll look twice.




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021