How to prevent corrosion in sprinkler system piping

Codes and Standards

How to prevent corrosion in sprinkler system piping

The technical committees responsible for NFPA 13, Installation of Sprinkler Systems, have been looking at ways to eliminate or reduce corrosion in sprinkler systems for several revision cycles.


By Peter Fabris, Contributing Editor | June 18, 2015
How to prevent corrosion in sprinkler system piping

Image: Pixabay

Corrosion in sprinkler system piping can be a costly problem if leaks occur, causing damage to the interior of a structure, according to Matt Klaus, Principal Fire Protection Engineer with the National Fire Protection Association. 

Replacing piping is no small expense, either. Corrosion can also cause blockages in the piping network, which can lead to an ineffective sprinkler system during a fire.

Corrosion can take on many forms, including oxidation, microbiologically influenced corrosion, and galvanic corrosion. The technical committees responsible for NFPA 13, Installation of Sprinkler Systems, have been looking at ways to eliminate or reduce corrosion in sprinkler systems for several revision cycles.

Reducing corrosion in dry systems can be achieved by eliminating all of the water from these systems after testing/activation and using alternative gases like nitrogen for charging these systems. For wet systems, limiting the amount of air in the system is the goal. Air trapped in pressurized sprinkler system piping results in an increase in the concentration of dissolved oxygen in the piping, enabling corrosion. Venting the trapped air in a wet system reduces this problem, so a revision to the wet system sprinkler system standard requires that a single air vent be installed for each system.

Depending upon the building geometry and sprinkler design, it is possible to trap air in many locations in the system, meaning a single vent may not be effective. Therefore, some stakeholders believe that the requirement adds cost to the property owner and the design team without any assurance that there is a long-term benefit to the system.

More tips and advice from the NFPA.

Related Stories

| Jan 16, 2013

Standards that include reflective roofs must take into account local climate

Roofs painted white can reflect heat and reduce warm-weather energy use, but in cooler regions like Minneapolis or Chicago, the issue of energy-efficiency is less straightforward.

| Jan 16, 2013

New standard for geothermal heat pump systems piping to be included in 2015 International Mechanical Code

NSF International, an independent global organization that writes standards, and tests and certifies products, has published the first in a series of American National Standards for Ground-Source Geothermal Piping Systems – NSF/ANSI 358-1.

| Jan 16, 2013

ANSI passes new safety standards for reinforcing steel and post-tensioning

The ANSI A10 Accredited Standards Committee for Construction and Demolition Operations recently approved amendments to the ANSI A10.9 Concrete and Masonry Standard.

| Jan 8, 2013

Congress passes Drywall Safety Act

Congress recently passed the Drywall Safety Act; President Barack Obama is expected to sign it soon.

| Jan 8, 2013

Building-integrated PVs could help boost green standards over the next few years

A developing technology could begin to have an impact on sustainable standards over the next few years.

| Jan 8, 2013

Revamp of codes among nine low tech steps to raise community resiliency

Updating of local zoning and building codes is one of nine low-tech steps that can boost sustainability and storm resiliency, according to this article.

| Jan 8, 2013

Group releases safety and building codes from 24 countries

Public.Resource.Org released 10,062 public safety documents including building codes covering 24 countries and 6 regions.

| Jan 8, 2013

Montana developing high-performance building standards for state projects

The Montana Department of Administration is developing a single building standard for all state facilities, and hopes to have a plan in place this spring.

| Jan 4, 2013

AGC economist says "fiscal cliff" deal will give construction a boost

The deal in Congress to avoid going over the so-called fiscal cliff "should encourage many businesses to go ahead with projects they have held in reserve," said Ken Simonson, chief economist of the Associated General Contractors of America.

| Jan 4, 2013

California standards on furnishings, insulation to be revised

California is revising the state’s standards on interior furniture and insulation to maintain or improve fire safety while reducing or eliminating the use of toxic chemicals.

boombox1
boombox2
native1

More In Category




halfpage1

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021