With a constant drive for operational efficiencies and reduction of costs under an outcome-based healthcare environment, there are increasing pressures to ensure that sustainability initiatives are not only cost effective and provide a return on investment, but socially and environmentally responsible. Oregon Health & Science University (OHSU) is in the business of wellness—the desired outcome.
An effective sustainability program within a healthcare environment is the hub of the wheel that can produce several outcomes, such as workforce engagement, that are key drivers for higher reimbursements within the healthcare mission. It’s also the prioritization of these potential outcomes that can drive the creation of the desired operating vision.
This is a challenging balance within an organization that has competing yet synergistic missions of healthcare, research, and academics. With an established operating vision as the foundation, the following provides a road map for achieving a highly effective sustainability program within OHSU’s healthcare mission.
BUILDING DESIGN & SYSTEMS
There are several benefits and results noted within the OHSU Fast Facts related to the design and systems that reflect the dedication to sustainability within a wellness environment. However, within this innovative approach are noted challenges that required strategic solutions to achieve the desired cost savings and operational functionality while balancing the desire to achieve high occupant and patient satisfaction.
MEP System Design. When designing the MEP systems for a sustainable building a common approach that can achieve the desired energy savings is to “right size” the mechanical and electrical systems. This involves system design with only the necessary capacity to serve the programs anticipated at the time of construction. By doing so, you reduce the added energy consumption while lowering your initial capital investment.
However, facility operators, who have significant experience with managing healthcare facilities, immediately understand the challenges that “right sizing” may cause. Healthcare facilities are in a perpetual state of change, constantly evolving to meet the needs and demands of the industry. Therefore, it is impossible to know during the project design phase, the long-term changes that will impact the capacity of these systems. By “right sizing” systems, future expansion and renovation possibilities may be limited.
In addition, in many areas of healthcare, there is a minimum of N+1 redundancy to meet the basic life support and other regulatory requirements. Special attention must be paid to the types of systems and the control sequencing to help ensure that maximum efficiencies can still be attained. As a result, additional operational cost impacts may be incurred due to a higher level of sophisticated programming, engineer skill-set and training required ensuring limited system disruption and/or operational impacts.
Balancing Innovative System Technology. The highly innovative system technology resulted in a design that included many firsts for a healthcare facility of its size and complexity. One of the key innovations was to install a membrane bioreactor wastewater treatment system that processes all of the sanitary waste on-site. The system transforms the wastewater into a non-potable water source and harvests rainwater and excess groundwater to reduce the dependence on municipal water supply by an astonishing 60%.
However, this innovative system is not without challenges. A membrane bioreactor is a living machine, and with the use of high level sterilants (used for disinfecting medical equipment) there is potential for significant disruptions to the waste system. To mitigate this risk, a comprehensive chemical waste disposal policy was created in collaboration with OHSU’s Environmental Health & Radiation Safety team to ensure occupants were adequately trained on the process of using and disposing of chemicals down drains.
In addition, on-going education was implemented to account for employee turnover and new chemical introduction. Signs were also posted above sinks and drainage areas that have a higher potential for chemical use to address complacent use.
Despite the noted water savings, the upfront cost of installing the system was significant, but was slightly offset by the deferral of system development fees. Also, an on-site wastewater treatment system requires ongoing operational costs, including daily lab testing, special environmental permits, and labor to oversee the treatment plant. Although, there was considerable thought for the financial investment, OHSU also focused on balancing their decision to reduce the impact on the environment and remain socially responsible in regard to the community’s wastewater system. This is a balance of planet, people, and profit—known as the three P’s of sustainability.
There were innovative design elements within the central utility plant (CUP), as well. The CUP utilizes a fuel source to generate power and then transfers the heat from this process into a heating source. Five natural-gas-fueled microturbines can transfer up to 300kw power resulting in the capability of generating up to 30% of the facility’s electricity. The heat generated by the turbines provides space heating, domestic water heating, as well as heating for three on-site swimming pools.
With power relatively cheap in the Pacific Northwest, the challenge is to ensure that efficiency of the turbines is maximized based on the demand for heat while balancing the need for electrical production as outlined within the microturbine carbon impact graphic below. If the costs creep slightly higher, the environmental impact reduction over using traditional methods of heat production and purchasing utilities will be a deciding factor when evaluating the three P’s.
SUSTAINABLE OPERATIONS
Environmental Services (EVS) - Cleaning. The EVS vendor, GCA Services, is a national janitorial company that provides cleaning services at the building. The GCA cleaning team has established a green cleaning program that reflects use of green cleaning practices and products.
To further enhance energy savings, GCA implemented a day cleaning schedule in 2011. This proved to be challenging in a healthcare environment so the hours were adjusted to create staggered afternoon start times based on the operating hours of each respective clinic. This allowed occupants to get to know their cleaner while limiting disruptions within exam rooms and other patient care areas. The benefits of day cleaning are as follows:
• Energy savings and environmental consciousness
• Improved occupant satisfaction via enhanced 1:1 occupant-cleaner relationships and confidence
• Office space is visibly and routinely well cleaned
• Employee responsibility and security
• Less turnover and enhanced productivity
As a LEED Platinum building, the operations team strives to promote green practices throughout the building. The selection of cleaning supplies is also a key component to establishing a green cleaning program especially with balancing the limitations of chemical usage with the on-site wastewater treatment system.
Healthcare requires a higher level of disinfection to prevent cross contamination of blood borne pathogens. Non-green disinfectants are used in patient care areas while green approved products are used in non-patient care areas. There is a balance in knowing when certain products are needed while also maintaining the green standard with the LEED certification requirements.
Waste Management. A fully comprehensive recycling program was implemented upon occupancy of the building through collaboration with the City of Portland’s Bureau of Planning & Sustainability. The program includes recycling for paper, plastic, tin, aluminum, glass, cardboard, light bulbs, batteries and composting.
But, how do you ensure that you are achieving an effective waste management program within a very busy patient care environment? Simple, create a competition and promote the benefits and results to enhance buy-in and a high level of engagement.
To promote better recycling habits, CHH does an annual waste audit to highlight the amount of recyclables that are being put in the trash. The audit is conducted on a regular business day with normal volume of occupants and visitors. The project team physically separates the entire waste stream during the audit period into its component parts, measures each waste type by weight and tracks the amount of recyclables that were properly diverted from the waste stream via the CHH recycling program.
Tenants are notified of their results and their overall performance compared to the previous year and the best performance is recognized and awarded. With promotion of the results and continuing tenant education, OHSU hopes to see improved results year after year as it creates a competitive environment among the tenants.
STRATEGIC COMMUNICATIONS
Occupant education is a main driver for ongoing buy-in and consistent satisfaction and should constantly evolve through various communication paths to achieve a broadly engaged audience. The web portal at www.southwaterfrontcampus.com serves as a centralized intranet that provides resources such as the tenant handbook, access to the Computerized Maintenance Management System (CMMS), and other general tools and announcements.
Building-wide, tenant meetings are held on a quarterly basis to provide general updates to department managers and service line contacts for the campus. This collaborative approach ensures there is a strong foundation for the program delivery as well as OHSU’s contribution to setting a high performance standard and results. A quarterly newsletter is distributed to tenants in the weeks following the tenant meeting, providing highlights on all information resented. It is the combination of collaborative meetings coupled with follow-up visual information via several communication paths that has contributed to a high level of occupant engagement.
In addition, an annual sustainability report is provided to OHSU and building occupants providing a visual synopsis of how the platform and LEED framework contribute to the overall program results and return on investment to reinforce dedication to the sustainable strategies implemented under the operating vision.
Surveys are also deployed to occupants annually, as well as via the CMMS throughout the year to identify areas of success and improvement. The high level of engagement is apparent within a busy healthcare environment with a high level of survey participation over the past nine years with a department response rate above 64% versus an industry-standard that is typically around only 20%. In addition to occupant engagement, you must have the right tools to deploy an effective program. A detailed playbook that defines program roles and responsibilities amongst team members will ensure consistent implementation and outcomes. The playbook serves as an invaluable training guide for new hire onboarding, as well as a blueprint for future growth.
Achieving sustainability in a healthcare environment can be challenging. A solutions oriented approach for developing systems, implementing technology and investing in team resources will aid in building the foundation necessary to deliver the desired results.
About the Author: Dyann Hamilton is an Alliance Director at CBRE with over 20 years of commercial real estate experience. She is responsible for on-site facilities and project management services, lease administration and accounting for over 1 million square feet of real estate in the South Water-front District for Oregon Health & Science University, Portland State University and Oregon State University. Her portfolio includes healthcare, research and academic use within LEED-Platinum Certified facilities.
Related Stories
| Sep 13, 2010
'A Model for the Entire Industry'
How a university and its Building Team forged a relationship with 'the toughest building authority in the country' to bring a replacement hospital in early and under budget.
| Sep 13, 2010
Data Centers Keeping Energy, Security in Check
Power consumption for data centers doubled from 2000 and 2006, and it is anticipated to double again by 2011, making these mission-critical facilities the nation's largest commercial user of electric power. With major technology companies investing heavily in new data centers, it's no wonder Building Teams see these mission-critical facilities as a golden opportunity, and why they are working hard to keep energy costs at data centers in check.
| Aug 11, 2010
Green Guide for Health Care launches pilot program, looks for participants
In first quarter 2010, the Green Guide for Health Care, in collaboration with Practice Greenhealth, is launching a one-year Green Guide for Health Care Operations Pilot Program for healthcare organizations engaged in any or all aspects of green operations initiatives, based on Green Guide v2.2 Operations section.
| Aug 11, 2010
JE Dunn, Balfour Beatty among country's biggest institutional building contractors, according to BD+C's Giants 300 report
A ranking of the Top 50 Institutional Contractors based on Building Design+Construction's 2009 Giants 300 survey. For more Giants 300 rankings, visit http://www.BDCnetwork.com/Giants
| Aug 11, 2010
EwingCole to merge with healthcare specialist Robert D. Lynn Associates
EwingCole, a nationally recognized architectural, engineering, interior design, and planning firm with more than 320 professionals, today announced that it will combine its practice with Robert D. Lynn Associates of Philadelphia, a 40-person firm with a robust portfolio of healthcare projects. The combination will create the Delaware Valley¹s largest and most comprehensive firm with an emphasis on healthcare architecture, and a national scope and presence.
| Aug 11, 2010
Jacobs, Arup, AECOM top BD+C's ranking of the nation's 75 largest international design firms
A ranking of the Top 75 International Design Firms based on Building Design+Construction's 2009 Giants 300 survey. For more Giants 300 rankings, visit http://www.BDCnetwork.com/Giants
| Aug 11, 2010
Architecture Billings Index flat in May, according to AIA
After a slight decline in April, the Architecture Billings Index was up a tenth of a point to 42.9 in May. As a leading economic indicator of construction activity, the ABI reflects the approximate nine to twelve month lag time between architecture billings and construction spending. Any score above 50 indicates an increase in billings.
| Aug 11, 2010
Construction employment declined in 333 of 352 metro areas in June
Construction employment declined in all but 19 communities nationwide this June as compared to June-2008, according to a new analysis of metropolitan-area employment data released today by the Associated General Contractors of America. The analysis shows that few places in America have been spared the widespread downturn in construction employment over the past year.
| Aug 11, 2010
Jacobs, Hensel Phelps among the nation's 50 largest design-build contractors
A ranking of the Top 50 Design-Build Contractors based on Building Design+Construction's 2009 Giants 300 survey. For more Giants 300 rankings, visit http://www.BDCnetwork.com/Giants
| Aug 11, 2010
VA San Diego Healthcare System Building 1 Seismic Correction
San Diego, Calif.
Three decades after its original construction in the early 1970s, the Veterans Affairs San Diego Healthcare System Building 1 fell far short of current seismic codes. This not only put the building and its occupants—patients, doctors, nurses, visitors, and administrative staff—at risk in the event of a major earthquake, it violated a California state mandate requiring all hospitals to either retrofit or rebuild.